SOCLAIR ELECTRONIC - SWISS MADE TRANSDUCERS AND CONVERTERS

Transducer for Thermocouples

General Description

These transducers convert the output voltage from a thermocouple into an output signal (e.g., 0-10 V or 4-20 mA) or into a frequency output (max. 10 kHz), which is linearly proportional to the thermovoltage. The measurement range and zero-point of the DIL-programmabale transducers are adjustable by DIL-switches in steps of 1 mV. All settings are calibrated. The DIL-switches also enable the selection of various operating modes (thermocouple type, voltage or current output).

Our newest generation of programmable transducers (IT 1XX, IT 2XX) allow the setting of almost any desirable range via a RS232-interface. This interface allows also the download of measurement values (AD-converter), calibration date, serial number and more.

  • Optionally with inductive isolation between input and output (isolating transducer), three port isolation on request. Test voltage between 1 kV and 3 kV.
  • Electronic reference junction for all common thermocouples - can be deactivated
  • Control LED for units with 24 V power supply
  • Fixed range types: input and output ranges can be ordered as required, factory calibration
  • Programmable types: all ranges/settings are calibrated, programmed via DIL-switches or via RS232.
  • Different housings available
  • Secure against short circuits, connection reversal, up to 30 VDC overvoltage.
  • Many options: Different isolaton classes, limit switch, multiplexer, digital interface, frequency output.

Overview/Prices

Housing

Modules for DIN-Rails, 23mm

Prices/Accuracy Class
Swiss Francs (CHF)
Type Output Power supply Range A C D
TCM 70 V 21-30V/ ±15V fixed 323.- 177.- 146.-
TCM 82 0/4-20mA 21-30V/ ±15V fixed 347.- 185.- 154.-
TCM90 V, 0/4-20mA 19-30V progr. (DIL) 377.- 195.- ----
TCM 80 4-20mA 2-D, 12-30V fixed 338.- 177.- 146.-
TCM 100 4-20mA 2-D, 13-30V progr. (DIL) 377.- 195.- ----
ISOT 70 V/Iso. 21-30V/ ±15V fixed 395.- 269.- 208.-
ISOT 90 V/Iso. 19-30V progr. (DIL) 421.- 278.- ----
ISOT 80 4-20mA/Iso. 2-D, 13.5-30V fixed 395.- 269.- 207.-
ISOT 100 4-20mA/Iso. 2-D, 13.5-30V progr. (DIL) 421.- 278.- ----
IT 270 V/Iso. 17-30V fixed (RS232) 315.- 220.- 171.-
IT 282 I/Iso. 17-30V fixed (RS232) 315.- 220.- 171.-
IT 290 V, 0/4-20mA/Iso. 17-30V progr. (RS232) ---- 242.- 200.-

For 3-port isolation add CHF 50.- to price



Housing

Modules for DIN-Rails, 6.2mm

Prices/Accuracy Class
Swiss Francs (CHF)
Type Output Power supply Range A C D
IT 170 V/Iso 13-30V fixed (RS232) 271.- 208.- 164.-
IT 182 0/4-20mA/Iso 13-30V fixed (RS232) 271.- 208.- 164.-
IT 190 V, 0/4-20mA/Iso 13-30V progr. (RS232) ---- 228.- 192.-

For 3-port isolation add CHF 10.- to price



Housing

Printed Circuit Board/Euro-Card Modules

Prices/Accuracy Class
Swiss Francs (CHF)
Type Output Power supply Range A C D
SIGT 10 V 14-30V/ ±15V fixed 308.- 162.- 146.-
SIGT 32 0/4-20mA 14-30V fixed 315.- 169.- 154.-
SIGT 15 V, 0/4-20mA 16-30V progr. (DIL) 314.- 184.- ----
SIGT 30 4-20mA 2-D, 9-30V fixed 308.- 162.- 138.-
SIGT 35 4-20mA 2-D, 10-30V progr. (DIL) 314.- 184.- ----
ISOT 10 V/Iso. 14-30V/ ±15V fixed 354.- 215.- 169.-
ISOT 30 4-20 mA/Iso. 2-D, 10-30V fixed 354.- 215.- 169.-
IT 210 V/Iso. 17-30V fixed (RS232) 271.- 192.- 150.-
IT 232 0/4-20 mA/Iso. 17-30V fixed (RS232) 271.- 192.- 150.-
IT 215 V, 0/4-20 mA/Iso. 17-30V progr. (RS232) ---- 221.- 178.-


Gehäuse

Modules for DIN-Heads (Type B)

Prices/Accuracy Class
Swiss Francs (CHF)
Type Output Power supply Range A C D
TCM 40 4-20mA 2-D, 12-30V fixed 308.- 169.- 138.-

Price for one item, consult distributor for discounts. Approx. price in EUR or $: CHF x 0.67. Please contact distributor for exact price.


Caption:
Iso.: Transducer with galvanic isolation between input and output (option: 3-port isolation).
2-D: 2-wire module (4-20 mA), power supply and signal over the same wire.
3P: 3-port-isolation (including power supply), test voltage 1 to 3 kV depending on module.
fixed: input and output range selected as desired (required range to be specified when ordering).
fixed (RS232): input and output range selected as desired (required range to be specified when ordering), programmind only in factory, option: potentiometer.
progr. (DIL): User programmable module (via DIL-switches), with potentiometer.
progr. (RS232): User programmable module (via RS232-interface), potentiometer as option.

When ordering, please specify:

  • Module type
  • Accuracy class (A, C, or D)
  • Input range (in °C, K or Ohm)
  • Type (K, J, E, etc.)
  • Output range (in mA, V or Hz)
  • Supply voltage (in V, uni- or bipolar)
  • Only the module type and accuracy class (A, C, D) has to be specified for programmable versions. If required, module can be precisely set for a specific range.

Detailed Datasheets:

Data sheet TCM/SIGT 10-100, ISOT 10-100 (download PDF-File, ca. 210 KB, version 21.12.2002)
Data sheet IT 170-190, IT 210-290 (download PDF-File, ca. 230 KB, version 3.1.2003)
Data sheet Analog to Frequency Converter (download PDF-File, ca. 220 KB, for Module Nr. 10-100)
Data sheet Analog to Frequency Converter (download PDF-File, ca. 220 KB, for Module Nr. 170-290)


--------------------------------------------------

--------------------------------------------------

URL: http://www.soclair.ch/catalog/tcm/
Last updated: January 15, 2003 by webmaster@soclair.ch

Copyright © 1996-2003 by Soclair Electronic. All rights reserved.