Transducers with Frequency Output
Technical Data
Accurancy of the Frequency OutputBasic error of max. 0.2% (incl. transmission error, calibration error and drift between 20-30°C). On delivery, the outputs of the measurement transducers are set to 5 kHz (max. 0.2% error). The calibration can alter slightly when the range is switched (SMD switches), switching error typ. 1% (max. 4% for 100, 200, 400 and 800 Hz). Input/Measurement Range
Power SupplyThe power supply for this module is the same as for the basis module, current consumption is around 20 mA greater. Bipolar power supply is not possible. A galvanically isolated power supply is available as an option (uses DC-DC converter). 3 port isolation is thus achieved (not suitable for mains voltages). Frequency OutputSquare impulses, amplitude determined by the voltage at input 3 (enable). The output impedance is around 600 Ohm (protection against short circuits and interference voltages). When the load resistance is 1 kOhm, a voltage splitter arises (600 Ohm/1 kOhm), which correspondingly reduces the voltage amplitude (to approx. 15 V for 24 V at the enable input). The galvanically isolated output stage eliminates earth loops and varying ground potentials. It is NOT suitable for mains voltages (max. 60 V). See the operating instructions for more information. Frequency RangeThe output frequency varies between 0 Hz and the max. output frequency, according to the magnitude of the input. In the programmable version (option), the maximum output frequency can be set via switches, in steps of 100 Hz (up to a max. of 20 kHz) Options
| ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]()
![]()
![]()